Low fouling fills, for slightly and medium polluted water
KVP 319 | KBP 320 | KVP 323 | KFP 327 | |
---|---|---|---|---|
Contact surface [m²/m³] | 144 | 142 | 125 | 125 |
Corrugation height [mm] | 19 | 20 | 23 | 27 |
Channels | Vertical flow | Vertical flow / off set | Vertical flow | Cross-fluted |
Easy to clean, for special operation conditions, for strongly polluted water
NET25 150 | FC20.30 | KFP 638 | FC70.34 | |
---|---|---|---|---|
Contact surface [m²/m³] | up to 130 | 110 | 70 | 94 |
Corrugation height [mm] | 20 | 30 | 38 | 34 |
Channels | Grid / diagonal | Cross-fluted | Cross-fluted | Grid / horizontal |
OVERVIEW: PLASDEK® COOLING FILLS MADE OF PVC
Highly efficient with large specific surface, suited for clean cooling water
KZC 312 | KFC 319 | |
---|---|---|
Contact surface [m²/m³] | 240 | 150 |
Corrugation height [mm] | 12 | 19 |
Channels | Cross-fluted | Cross-fluted |
Low fouling fills, for slightly and medium polluted water
KVC 319 | KBC 320 | KFC 327 | |
---|---|---|---|
Contact surface [m²/m³] | 144 | 142 | 125 |
Corrugation height [mm] | 19 | 20 | 27 |
Channels | Vertical flow | Vertical flow / off set | Cross-fluted |
General Technical Data of 2H PLASdek® Fills
PP | PVC | |
---|---|---|
Void ratio [%] | > 97 | |
Length max [mm] | 2400 | |
Width max [mm] | 600 | |
Standard height [mm] | 300 or 600 | |
Continuous operation temperature [°C] | 80 | 55 |
Max. operation temperature (short term) [°C] | 90 | 60 |
Maximum application temperature:
The operational temperature should be measured at the inlet pipe of the system and should not exceed the maximum temperature stated above.
High temperature applications:
Fill media in high temperature in PP (up to 100°C) available on request.
Flammability:
Products in flame retardant version according to American (ASTM E84, UL 94) and European standards (DIN 4102, NF P 92-501) are available on request. National regulations on fire protection should be taken into consideration before choosing a product.
KPP 312 KPC 312 |
KZP 312 KZC 312 |
KFP 319 KFC 319 |
KFP 327 KFC 327 |
KFP 638 KFC 638 |
|
---|---|---|---|---|---|
Contact surface [m²/m³] | 232 | 240 | 150 | 125 | 70 |
Void ratio [%] | > 97 | > 97 | > 97 | > 97 | > 97 |
Corrugation height | 12 | 12 | 19 | 27 | 38 |
Note | KFP/KGP/KVP/KBP = Fills in PP KFC/KGC/KVC/KBC = Fills in PVC |
KVP 319 KVC 319 |
KGP 320 KGC 320 |
KBP 320 KBC 320 |
KVP 323 KVC 323 |
|
---|---|---|---|---|
Contact surface [m²/m³] | 144 | 142 | 142 | 125 |
Void ratio [%] | > 97 | > 97 | > 97 | > 97 |
Corrugation height | 19 | 20 | 20 | 23 |
Note | KFP/KGP/KVP/KBP = Fills in PP KFC/KGC/KVC/KBC = Fills in PVC |
FC20.30 | FC70.34 | |
---|---|---|
Contact surface [m²/m³] | 110 | 94 |
Void ratio [%] | > 95 | > 93 |
Corrugation height | 30 | 34 |
Note | Our splash cooling fills are made of PP |
NET 25 150 | NET 38 150 | |
---|---|---|
Contact surface [m²/m³] | up to 130 | up to 130 |
Void ratio [%] | > 97 | > 97 |
Corrugation height | 20 | 20 |
Note | Our trickle grid fills are made of PP |